翻訳と辞書
Words near each other
・ Blemus discus
・ Blemyah
・ Blencarn
・ Blencathra
・ Blencoe Falls
・ Blencoe v British Columbia (Human Rights Commission)
・ Blencoe, Iowa
・ Blencogo
・ Blencow
・ Blencow railway station
・ Blencowe
・ Blend
・ Blend (album)
・ Blend modes
・ Blend Saleh
Blend time
・ Blend word
・ Blend4Web
・ Blenda
・ Blenda Gay
・ Blenda Ljungberg
・ Blenda, Podlaskie Voivodeship
・ Blende
・ Blende mine
・ Blende, Colorado
・ Blendecques
・ Blended (film)
・ Blended 328
・ Blended finance
・ Blended learning


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Blend time : ウィキペディア英語版
Blend time
Blend time, sometimes termed mixing time, is the time to achieve a predefined level of homogeneity of a tracer in a mixing vessel. Blend time is an important parameter to evaluate the mixing efficiency of mixing devices.〔Bai, G., Armenante, P. M., Plank, R. V., “Experimental and Computational Determination of Blend Time in USP Dissolution Testing Apparatus II,” Journal of Pharmaceutical Sciences, Volume 96, Issue 11, Pages 3072-3086, 2007〕 In order to make this definition valid, the tracer should be in the same physical phase (e.g. liquid) as the bulk material.

Blend time can be determined either with experiments or numerical modeling, such as computational fluid dynamics (CFD).〔Campolo M, Soldati A. 2004. Numerical evaluation of blend time in a tank reactor stirred by a magnetically driven impeller. Ind Eng Chem Res 43:6836–6846.〕〔Yeoh SL, Papadakis G, Yianneskis M. 2005. Determination of blend time and degree of homogeneity in stirred vessels with large eddy simulation. Chem Eng Sci 60:2293–2302.〕 The experimental methods to determine the blend time in liquid include conductivity method and discoloration method.〔〔Brown ARD, Jones NP, Middleton CJ, Papadopoulos G, Arik EB. 2004. Experimental methods. In: Paul LE, Atiemo-Obeng AV, Kresta MS, editors. Handbook of Industrial Mixing. Hoboken, NJ: John Wiley & Sons, Inc. (Chapter 4)〕 The conductivity method requires a conductivity probe to present in the target system, which make it an intrusive method because the existence of the probe might change the mixing efficiency of the mixing device. Discoloration method does not require any probe which makes it a non-intrusive method. However, the color detection device (sometimes the human eye) needs to be calibrated against the conductivity method.〔 Both methods are usually applied to monitor the concentration of the tracer in the most difficult to mix locations such as the area adjacent to the impeller shaft.
The benefit of numerical modeling is that once the modeling is completed, the blend time of any predetermined level of homogeneity of any location within the mixing system can be predicted, which is impossible to accomplish by experimental methods. However, numerical modeling needs to be validated by experimental methods.〔
== References ==


抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Blend time」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.